HomeMy WebLinkAboutOrdinance No. 2664-2012Suggested by: Administration ls� CITY OF KENAI KENAI. ALASKA ORDINANCE NO. 2664 -2012 AN ORDINANCE OF THE COUNCIL OF THE CITY OF KENAI, ALASKA, AMENDING CHAPTER 4.32, RESIDENTIAL CODE, BY ADOPTING THE 2009 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND MAKING LOCAL AMENDMENTS. WHEREAS, the City previously adopted the International Residential Code, 2006 Edition, of the International Code Council, including the appendices with certain local amendments; and, WHEREAS, the International Code Council updated the International Residential Code in 2009; and, WHEREAS, the City's Building Official accordingly recommends adoption of the 2009 Edition of the International Residential Code, with certain amendments; and, WHEREAS, it is in the best interest of the City to adopt the 2009 Edition of the International Residential Code and the updated standards therein, as amended for the City, in order to protect the health, safety, and welfare of its citizens. NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF KENAI, ALASKA, as follows: Section 1. Form: This is a Code ordinance. Section 2. Amendment of Chanter 4.32 of the Kenai Municipal Code: The Kenai Municipal Code, Chapter 4.32, Residential Code, is hereby amended as follows: Chapter 4.32 RESIDENTIAL CODE 4.32.010 Adoption. 4.32.015 Local amendments to the 200[6]9 International Residential Code. 4.32.020 Building Official. 4.32.030 Fee schedule. 4.32.010 Adoption. There is hereby adopted for the purpose of establishing rules and regulations for the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one and two family dwellings and multiple single - family dwellings, that certain code known as the "International Residential Code," 200[6]9 Edition, of the International Code Council, including the appendices, except for such portions as are hereafter deleted, Ordinance No. 2664 -2012 Page 2 of 19 modified, or amended; and the same is hereby adopted and incorporated as fully as if set out verbatim herein. 4.32.015 Local amendments to the 200[6]9 International Residential Code. [R105.5. ADD THE FOLLOWING: A BUILDING PERMIT SHALL EXPIRE TWO (2) YEARS AFTER THE DATE OF ISSUANCE UNLESS AN EXTENSION HAS BEEN GRANTED AS PROVIDED IN THIS SUBSECTION. R107.3 TEMPORARY POWER. AMEND THE LAST SENTENCE BY CHANGING "ICC ELECTRICAL CODE" TO "ELECTRICAL CODE ADOPTED BY KMC." R108.3 BUILDING PERMIT VALUATIONS. ADD THE FOLLOWING AFTER THE FIRST SENTENCE: THE BUILDING VALUATION DATA TABLE SHOWN IN THE LATEST EDITION OF THE BUILDING SAFETY JOURNAL PUBLISHED BY THE INTERNATIONAL CODE COUNCIL SHALL BE USED TO DETERMINE VALUE. R108.4 RELATED FEES. ADD THE FOLLOWING AFTER THE FIRST SENTENCE: ANY PERSON WHO COMMENCES ANY WORK ON A OBTAINING THE NECESSARY PERMITS SHALL BE SUBJECT FEE, EQUAL TO THE COST OF THE BUILDING PERMIT, ADDITION TO THE REQUIRED PERMIT FEES. SECTION R112 BOARD OF APPEALS. DELETE ENTIRE SECTION. REFER TO "CHAPTER 4.40 OF KMC." New Text Underlined; [DELETED TEXT BRACKETED] BUILDING BEFORE TO AN ADDITIONAL THAT SHALL BE IN Ordinance No. 2664 -2012 Page 3 of 19 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA. ADD THE FOLLOWING INFORMATION IN THE TABLE: GROUND SNOW LOAD 70 PSF WIND SPEED 100 MPH SEISMIC DESIGN CATEGORY D2 SUBJECT TO DAMAGE FROM: WEATHERING YES, SEVERE FROST LINE DEPTH 42" TERMITE NO DECAY NO WINTER DESIGN TEMPERATURE -18 DEG F FLOOD HAZARDS NO ICE SHIELD UNDER- LAYMENT REQUIRED YES AIR FREEZING INDEX 3000 MEAN ANNUAL TEMPERATURE 35 DEGREES R301.2.2.1.1 ALTERNATE DETERMINATION OF SEISMIC DESIGN CATEGORY. DELETE PARAGRAPHS R301.2.2.1.L, R301.2.2.1.2, R301.2.2.2, AND TABLE R301.2.2.1.1 AND REPLACE WITH THE FOLLOWING: THE SEISMIC DESIGN CATEGORY FOR KENAI SHALL BE D2. R309.1 OPENING PROTECTION FOR FIRE RATINGS FOR ATTACHED GARAGES. AMEND BY ADDING A THIRD SENTENCE TO READ AS FOLLOWS: DOORS SHALL BE SELF - CLOSING AND HAVE SMOKE GASKETS AT TOP AND SIDES OF DOORS AND ADJUSTABLE THRESHOLD OR SWEEP. R309.2 SEPARATION REQUIRED. AMEND BY DELETING THE FIRST TWO SENTENCES AND REPLACING WITH THE FOLLOWING: New Text Underlined; [DELETED TEXT BRACKETED] i Ordinance No. 2664 -2012 Page 4 of 19 A GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA WITH A ONE -HOUR OCCUPANCY SEPARATION. THE OCCUPANCY SEPARATION MAY BE LIMITED TO THE INSTALLATION OF APPROVED MATERIALS APPROVED FOR ONE -HOUR FIRE RESISTANCE CONSTRUCTION ON THE GARAGE SIDE ONLY. 5/8 TYPE X GYPSUM WALLBOARD WILL BE CONSIDERED ADEQUATE PROTECTION FOR ONE -HOUR CONSTRUCTION ON THE GARAGE SIDE AT RATED WALLS AND CEILINGS. ALL PLASTIC PIPE SUCH AS CONDENSATE LINES, VACUUM LINES, DRAIN LINES, WASTE LINES AND VENT LINES REQUIRE AN APPROVED TESTED FIRE COLLAR OR EQUIVALENT AT RATED WALL AND CEILING PENETRATIONS ON GARAGE SIDE ONLY. ALL FERROUS METAL PIPE PENETRATIONS ARE REQUIRED TO BE FILLED WITH GYPSUM WALLBOARD COMPOUND OR OTHER APPROVED MATERIALS. FIRE DAMPERS NEED NOT BE INSTALLED IN AIR DUCTS PASSING THROUGH THE WALL, FLOOR, OR CEILING SEPARATING GARAGE FROM THE DWELLING, PROVIDED SUCH DUCTS WITHIN THE GARAGE ARE CONSTRUCTED OF STEEL HAVING THICKNESS NOT LESS THAN 0.019 INCH (0.48 MM) (NO. 26 GALVANIZED SHEET GAUGE) AND HAVE NO OPENING INTO THE GARAGE. ACCESS TO A CRAWL SPACE FROM A GARAGE SHALL MEET MINIMUM REQUIREMENTS OF SELF - CLOSING, TIGHT FITTING, SOLID WOOD DOOR MEASURING 1 3/8 INCHES OR GREATER IN THICKNESS, OR EQUIVALENT LAMINATED PLYWOOD OR COMBINATION PLYWOOD AND PROPERLY SECURED 5/8 INCH TYPE X GYPSUM WALLBOARD OR 20- MINUTE APPROVED DOOR ASSEMBLY. R313.4 CARBON MONOXIDE DETECTORS. ADD A NEW SUBSECTION, R313.4, CARBON MONOXIDE DETECTORS, TO READ AS FOLLOWS: CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON EACH FLOOR LEVEL OF DWELLING UNITS. WHERE THERE ARE SLEEPING ROOMS ON A FLOOR, THE DETECTOR SHALL BE PLACED OUTSIDE OF THE SLEEPING ROOMS. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS CLOSED. ALL CARBON MONOXIDE DETECTORS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE. R313.4.1 ALTERATIONS, REPAIRS, AND ADDITIONS. ADD A NEW SUBSECTION, R313.4.1, ALTERATIONS, REPAIRS, AND ADDITIONS, TO READ AS FOLLOWS: WHEN INTERIOR ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH CARBON MONOXIDE DETECTORS AS REQUIRED IN SECTION R313.4 AND R313.4.1. New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 5 of 19 R313.4.2 POWER SOURCE. ADD A NEW SUBSECTION, R313.4.2, POWER SOURCE, TO READ AS FOLLOWS: IN NEW CONSTRUCTION, THE REQUIRED CARBON MONOXIDE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING SYSTEM, AND WHEN PRIMARY POWER IS INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVER CURRENT PROTECTION. CARBON MONOXIDE DETECTORS SHALL BE PERMITTED TO BE ELECTRICAL OUTLET TYPE WITH BATTERY BACK UP WHEN INSTALLED IN EXISTING BUILDINGS THAT UNDERGO ALTERATIONS, REPAIRS, OR ADDITIONS THAT DO NOT RESULT IN THE REMOVAL OF THE INTERIOR WALL OR CEILING FINISHES EXPOSING THE STRUCTURE. R314.1.2 THERMAL BARRIER. ADD THE FOLLOWING: EXCEPTION: FOAM PLASTICS USED IN CRAWL SPACE AREAS DO NOT REQUIRE THERMAL BARRIER PROVIDED THE FOLLOWING CONDITIONS ARE MET: ENTRY TO CRAWLSPACE IS ONLY TO SERVE UTILITIES. 2. THERE ARE NO INTERCONNECTED BASEMENT AREAS. 3. AIR TO THE CRAWL SPACE IS NOT CIRCULATED TO OTHER PARTS OF THE BUILDING. 4. FOAM PLASTIC DOES NOT EXCEED A 2 -INCH THICKNESS AND A 2.5 POUNDS PER CUBIC FOOT NOMINAL DENSITY. 5. VENTILATION COMPLYING WITH SECTION R408 IS PROVIDED. 6. NO GAS -FIRED EQUIPMENT IS LOCATED IN CRAWL SPACE. R318 MOISTURE VAPOR RETARDERS. DELETE PARAGRAPH AND EXCEPTIONS AND ADD THE FOLLOWING: VAPOR RETARDERS. ALL EXTERIOR WALL, CEILING, ROOF AND FLOOR ASSEMBLIES WHICH ENCLOSE HEATED SPACES AND WHICH ARE EXPOSED TO OUTDOOR AMBIENT TEMPERATURES SHALL BE PROTECTED AGAINST WATER VAPOR TRANSMISSION. ASSEMBLIES NOT OTHERWISE OF IMPERMEABLE New Tent Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 6 of 19 CONSTRUCTION SHALL HAVE INSTALLED, ON THE HEATED SIDE OF THE INSULATION OR AIR SPACES, VAPOR RETARDERS HAVING A PERM RATING OF 0.06 MINIMUM (EQUIVALENT TO 6 MILS POLYETHYLENE SHEETING) OR OTHER MATERIAL APPROVED BY THE BUILDING OFFICIAL. R319.3 FASTENERS DELETE EXCEPTION 1. R401.1 APPLICATION. ADD THE FOLLOWING EXCEPTION: WOOD FOUNDATIONS SHALL HAVE A 16 -INCH X 10 -INCH REINFORCED CONCRETE FOOTING MINIMUM. R402.1.3 RESTRAINT FOR WOOD FOUNDATIONS. ADD A NEW SUBSECTION, R402.1.3, RESTRAINT FOR WOOD FOUNDATIONS, TO READ AS FOLLOWS: BASEMENT. A 4 -INCH THICK CONCRETE SLAB POURED AGAINST THE STUDS. IF A WOODEN SCREED IS USED, IT SHALL BE DOUGLAS FIR OR HEM FIR PRESSURE TREATED IN ACCORDANCE WITH AWPA C22 WITH A.6 RETENTION. CRAWLSPACE. OPTION 1: A MINIMUM 5 -INCH WIDE BY 4 -INCH DEEP CONCRETE CURB POURED AGAINST THE INSIDE FACE OF THE STUDS. THE KICKER SHALL BE REINFORCED WITH A CONTINUOUS HORIZONTAL NO. 3 REINFORCING BAR. IF THE KICKER IS NOT POURED WITH THE CONTINUOUS CONCRETE FOOTING, IT MAY BE POURED LATER PROVIDED VERTICAL #3 REINFORCING BARS X10 INCHES LONG SHALL BE CAST INTO THE FOOTING AT 2 FEET ON CENTER. THEY SHALL EXTEND 2 INCHES ABOVE THE TOP OF THE FOOTING. THE CONTINUOUS #3 BAR SHALL BE SECURED TO THE VERTICAL #3 BARS. OPTION 2: INSTALLATION OF PRESERVATIVE TREATED 4" X 4 "S WITH A MINIMUM 1/2" X 12" GALVANIZED ANCHOR BOLTS AT 24" O.C. INSTALLED IN FOOTING AGAINST THE INSIDE FACE OF STUDS ALONG THE ENTIRE PERIMETER. EXCEPTION: THE ABOVE NEED NOT APPLY IF A SUITABLE ALTERNATE DESIGN IS PREPARED BY AN ENGINEER REGISTERED IN THE STATE OF ALASKA AND IS APPROVED BY THE BUILDING OFFICIAL. R402.1.4 DAMPPROOFING FOR WOOD FOUNDATION WALLS. New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 7 of 19 ADD A NEW SUBSECTION, R402.1.4, DAMPPROOFING FOR WOOD FOUNDATION WALLS, TO READ AS FOLLOWS: APPROVED DAMPPROOFING SHALL BE APPLIED OVER THE BELOW -GRADE PORTION OF EXTERIOR BASEMENT AND CRAWLSPACE WALLS PRIOR TO BACKFILLING. A TREATED LUMBER OR PLYWOOD STRIP SHALL BE ATTACHED TO THE WALL TO COVER THE TOP EDGE OF THE APPROVED DAMPPROOFING. THE WOOD STRIP SHALL EXTEND AT LEAST TWO (2) INCHES ABOVE AND FIVE (5) INCHES BELOW FINISH GRADE LEVEL TO PROTECT THE APPROVED DAMPPROOFING FROM EXPOSURE TO LIGHT AND FROM MECHANICAL DAMAGE AT OR NEAR GRADE. THE JOINT BETWEEN THE STRIP AND THE WALL SHALL BE CAULKED FULL LENGTH PRIOR TO FASTENING THE STRIP TO THE WALL. ALTERNATIVELY, BRICK, STUCCO, OR OTHER COVERING APPROPRIATE TO THE ARCHITECTURAL TREATMENT MAY BE USED IN PLACE OF THE WOOD STRIP. THE APPROVED DAMPPROOFING SHALL EXTEND DOWN TO THE BOTTOM OF THE CONCRETE FOOTING. R403.1.1 MINIMUM SIZE. REVISE THE THIRD SENTENCE TO READ "ALL FOOTINGS SHALL BE AT LEAST 10 INCHES IN THICKNESS." R403.1.3 SEISMIC REINFORCING. REVISE THE SECOND PARAGRAPH FIRST SENTENCE BY CHANGING "4 FEET" TO "24 INCHES." REVISE THE THIRD PARAGRAPH FIRST SENTENCE BY CHANGING THE NUMBER "4" TO "5" AND THE WORDS "FOUR FEET" TO "32 INCHES." REVISE THE EXCEPTION BY DELETING THE WORDS "PLAIN CONCRETE FOOTINGS WITHOUT LONGITUDINAL REINFORCEMENT SUPPORTING WALLS AND," AND ADD THE FOLLOWING: "PROVIDED WOOD FRAMING IS MECHANICALLY TIED TO ISOLATED FOOTINGS." R403.1.3.1 FOUNDATIONS WITH STEMWALLS. REVISE TO READ AS FOLLOWS: FOUNDATIONS WITH STEMWALLS SHALL BE PROVIDED WITH A MINIMUM OF ONE NO. 5 BAR AT THE TOP OF THE WALL FOR CONCRETE MASONRY UNIT STEMWALLS, ONE NO. 4 BAR AT THE TOP OF THE WALL FOR POURED CONCRETE STEMWALLS, AND TWO NO. 5 BARS AT THE BOTTOM OF ALL FOOTINGS. R403.1.3.2 SLABS -ON- GROUND WITH TURNED -DOWN FOOTINGS. REVISE THE FIRST SENTENCE BY CHANGING THE NUMBER "4" TO "5." New Text Underlined; ]DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 8 of 19 REVISE THE EXCEPTION BY CHANGING THE WORDS "ONE NO. 5 BAR" TO "TWO NO. 5 BARS" AND DELETING THE WORDS "OR TWO NO. 4 BARS." R403.2 FOOTINGS FOR WOOD FOUNDATIONS. DELETE ENTIRE PARAGRAPH AND REPLACE WITH THE FOLLOWING: WOOD FOUNDATIONS SHALL HAVE A 16- INCH -WIDE X 10- INCH -THICK CONCRETE FOOTING MINIMUM. R404.1.4 SEISMIC DESIGN CATEGORIES D1 AND D2. REVISE SUBSECTION 1. TO READ "MINIMUM REINFORCEMENT SHALL CONSIST OF NO. 4 HORIZONTAL BAR PLACED AT 16" ON CENTER FOR POURED CONCRETE WALLS AND NO. 5 HORIZONTAL BAR PLACED AT 48" ON CENTER FOR CMU WALLS." REVISE SUBSECTION 4 BY DELETING THE FOLLOWING WORD "PLAIN" IN TWO LOCATIONS AND ADDING AT THE END OF THE SENTENCE "AND SUPPORTING ONE FLOOR ONLY." REVISE SUBSECTION 5 BY DELETING THE WORD "PLAIN." REVISE SECOND PARAGRAPH BY CHANGING THE NUMBER "3" TO "5" AND THE WORDS "4 FEET" TO "32 INCHES" AND ADDING TO THE END OF THE PARAGRAPH "AND MINIMUM VERTICAL REINFORCEMENT OF ONE NO. 4 BAR LOCATED A MAXIMUM OF 24 INCHES ON CENTER IN POURED CONCRETE WALLS." REVISE BY DELETING THE LAST PARAGRAPH. R404.2 WOOD FOUNDATION WALLS. DELETE THE FOLLOWING FROM THE FIRST SENTENCE: "AND WITH THE DETAILS SHOWN IN FIGURES R403.1(2) AND R403.L(3)." R404.3 WOOD SILL PLATES. DELETE THE PARAGRAPH AND SUBSTITUTE WITH THE FOLLOWING: WOOD SILL PLATES SHALL BE MINIMUM 2 -INCH X 6 -INCH AND SHALL BE BOLTED TO THE FOUNDATION OR FOUNDATION WALL WITH NOT LESS THAN TEN (10) INCH -LONG BY FIVE- EIGHTHS (5/8) INCH NOMINAL DIAMETER GALVANIZED STEEL BOLTS EMBEDDED AT LEAST SEVEN (7) INCHES INTO THE CONCRETE OR IN FULLY GROUTED CELLS OF REINFORCED MASONRY AND SPACED NOT MORE THAN FOUR (4) FEET ZERO (0) INCHES APART. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIECE WITH ONE BOLT LOCATED WITHIN 12 INCHES OF EACH END OF EACH PIECE WOOD SILL PLATES MUST BE TREATED MATERIAL SPECIFIED IN SECTION R323.1. New Text Underlined: [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 9 of 19 R404.4.6.2 HORIZONTAL REVISE THE FIRST SENTENCE BY CHANGING THE NUMBER "48" TO "16." REVISE THE SECOND SENTENCE BY CHANGING THE NUMBER "36" TO "16." :aa EXCEPTION: OR PER MANUFACTURER'S REQUIREMENTS. R404.4.6.4 VERTICAL ADD NEW SECTION TO READ: VERTICAL REINFORCEMENT SHALL BE A MINIMUM OF NO. 4 VERTICAL REINFORCING BAR PLACED AT 24 INCHES ON CENTER. R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING. DELETE SECTION AND SUBSTITUTE WITH THE FOLLOWING: EXCEPT WHERE REQUIRED TO BE WATERPROOFED BY SECTION R406.2, IN DWELLING UNITS ONLY FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLE SPACES LOCATED BELOW GRADE SHALL BE DAMPPROOFED FROM THE TOP OF THE FOOTING TO THE FINISHED GRADE AND DAMPPROOFING SHALL COVER THE TOP OF THE FOOTING, AND LAP OVER THE OUTER EDGE A MINIMUM OF 1 INCH. MASONRY WALLS SHALL BE DAMPPROOFED WITH A BITUMINOUS COATING, 3 POUNDS PER SQUARE YARD (1.63 KG /M2) OF ACRYLIC MODIFIED CEMENT, 1/8 -INCH (3.2 MM) COAT OF SURFACE- BONDING MORTAR COMPLYING WITH ASTM C 887 OR ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2. CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE ABOVE LISTED DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR OF THE WALL. FOUNDATION WALLS THAT ARE BACKFILLED ON BOTH SIDES, SUCH AS THOSE USED IN CONJUNCTION WITH A "SLAB ON GRADE" DO NOT REQUIRE DAMPPROOFING OR WATERPROOFING. R406.2 CONCRETE MASONRY FOUNDATION WATERPROOFING. DELETE THE FOLLOWING WORDS FROM THE SECOND SENTENCE: 6 MIL (0.15 MM) POLYVINYL CHLORIDE, 6 MIL (0.15 MM) POLYETHYLENE. ADD THE FOLLOWING WORDS: FOUNDATION WALLS THAT ARE BACKFILLED ON BOTH SIDES, SUCH AS THOSE USED IN CONJUNCTION WITH A "SLAB ON GRADE" DO NOT REQUIRE DAMPPROOFING OR WATER PROOFING. i New Text Underlined; )DELETED TEXT BRACKETED) Ordinance No. 2664 -2012 Page 10 of 19 /- R406.3.2 BELOW GRADE MOISTURE BARRIER. DELETE AND SUBSTITUTE THE FOLLOWING: FOUNDATION WALLS LOCATED BELOW GRADE SHALL BE DAMPPROOFED WITH EITHER 2 -PLY OF 15 LB. HOT - MOPPED FELT OR 1 PLY OF 30 LB. HOT - MOPPED FELT OR OTHER APPROVED MATERIALS. R407.2 STEEL COLUMN PROTECTION. DELETE THIS SECTION IN ITS ENTIRETY. R408.6 FINISHED GRADE. DELETE THIS SECTION IN ITS ENTIRETY. R702.3.1 MATERIALS. ADD A SENTENCE TO LAST PARAGRAPH AS FOLLOWS: WATER RESISTANT GYPSUM BOARD SHALL NOT BE USED ON EXTERIOR WALLS. R702.3.6 FASTENING. ADD THE FOLLOWING SENTENCE AT THE END OF THE PARAGRAPH: GYPSUM BOARD APPLIED IN CEILINGS SHALL BE ATTACHED WITH SCREWS. NAILS ARE NOT ALLOWED. R802.3 FRAMING DETAILS. AMEND SUBSECTION 802.3 BY ADDING A PARAGRAPH AS FOLLOWS: MINIMUM DEPTH FROM ROOF SHEATHING TO WALL PLATE AT EXTERIOR WALLS TO BE 9 INCHES ON DWELLING UNITS. R802.10.2 DESIGN. ADD THE FOLLOWING SENTENCE AT THE END OF THE PARAGRAPH: MINIMUM DEPTH OF TRUSS AT EXTERIOR WALL PLATE TO BE 9 INCHES ON DWELLING UNITS. R806.1 VENTILATION REQUIRED. ADD THE FOLLOWING SENTENCE TO END OF PARAGRAPH: New Test Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 11 of 19 A NON - VENTILATED ROOF SYSTEM MAY BE ALLOWED AS AN ALTERNATE METHOD WHEN ITS DESIGN IS APPROVED BY THE BUILDING OFFICIAL. R905.2.2 SLOPE. DELETE THE PARAGRAPH AND REPLACE WITH THE FOLLOWING: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF THREE UNITS VERTICAL IN 12 UNITS HORIZONTAL OR GREATER. UNDERLAYMENT SHALL BE IN ACCORDANCE WITH SECTION R905.2.7 AND ICE PROTECTION SHALL BE IN ACCORDANCE WITH R905.2.7.1. R905.2.7 UNDERLAYMENT APPLICATION. DELETE PARAGRAPH AND REPLACE WITH THE FOLLOWING: FOR ROOF SLOPES FROM 3 VERTICAL UNITS IN 12 HORIZONTAL UNITS (3:12) UP TO 4 VERTICAL UNITS IN 12 HORIZONTAL UNITS (4:12), UNDERLAYMENT SHALL BE TWO LAYERS OF NON - PERFORATED TYPE 15 FELT APPLIED SHINGLE FASHION. UNDERLAYMENT SHALL BE INSTALLED STARTING WITH A 19 -INCH LAP OVER ICE PROTECTION. EACH SUBSEQUENT SHEET SHALL BE LAPPED 19 INCHES HORIZONTALLY, CONTINUING TO THE RIDGE, FASTENED SUFFICIENTLY TO HOLD IN PLACE. FOR SLOPES 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), OR GREATER UNDERLAYMENT SHALL BE ONE LAYER OF TYPE 15 FELT. UNDERLAYMENT SHALL BE INSTALLED STARTING WITH 4 -INCH LAP OVER ICE PROTECTION. EACH SUBSEQUENT LAYER SHALL BE LAPPED 2 INCHES HORIZONTALLY AND 4 INCHES VERTICALLY TO SHED WATER CONTINUING TO THE RIDGE, FASTENED SUFFICIENTLY TO HOLD IN PLACE. ICE PROTECTION WILL BE IN ACCORDANCE WITH R905.2.7.1. R905.2.8 FLASHING ADD THE FOLLOWING AT THE END OF THE PARAGRAPH: FLASHING SHALL BE NOT LESS THAN 4 INCHES BY 4 INCHES IN WIDTH. R905.9.1 SLOPE. DELETE THE WORDS: "EXCEPT FOR COAL -TAR BUILT -UP ROOFS, WHICH SHALL HAVE A DESIGN SLOPE OF A MINIMUM ONE - EIGHTH UNIT VERTICAL IN 12 UNITS HORIZONTAL (1- PERCENT SLOPE)." R905.10.2 SLOPE. ADD THE FOLLOWING TO THE END OF THE PARAGRAPH: New Teat Underlined; ]DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 12 of 19 INSTALL UNDERLAYMENT UNDER ALL METAL ROOF PANELS. UNDERLAYMENT SHALL BE ONE LAYER OF TYPE 15 FELT. UNDERLAYMENT SHALL BE INSTALLED, STARTING WITH 4 -INCH LAP -OVER ICE PROTECTION. EACH SUBSEQUENT LAYER SHALL BE LAPPED 2 INCHES HORIZONTALLY, AND 4 INCH VERTICALLY TO SHED WATER CONTINUING TO THE RIDGE. FASTEN SUFFICIENTLY TO HOLD IN PLACE. ICE PROTECTION SHALL BE IN ACCORDANCE WITH R905.2.7.1." CHAPTERS 11 -42. AMEND BY DELETING CHAPTERS 11 -42 IN ITS ENTIRETY AND REFERRING TO APPLICABLE CODES AS ADOPTED IN KMC.] The International Residential Code (2009 Edition) is adopted by reference with the following revisions: R105.2 Work Exempt from permit. Amend #1 to read: One story accessory structures used as tool and storage sheds playhouses and similar uses, provided the floor area does not exceed 120 square feet. Permits are required for any electrical, mechanical or plumbing provided. Amend #10 to read: Free standing decks not structurally attached to another building and not exceeding 30 inches above grade. R105.5 Expiration. Amend by adding a new sentence to read: A building permit shall expire two (2) years after the date of issuance unless an extension has been granted as provided in this subsection. R107.3 Temporary power. Amend by deleting the reference "ICC Electrical Code" and replacing it with "Electrical Code adopted by KMC." R108.2 Schedule of Permit Fees Delete and replace with: The fees for construction of Group R -3 and Grout) U -1 occupancies, or portions thereof, are as set forth in the City's schedule of rates, charges and fees adopted by the City Council. Plan review fees shall be fifty percent (50 %) of the building permit fee for Group R -3 and Group U -1. Plan review fees shall be paid at the time applications for building permits are submitted. R108.3 Building permit valuations. Amend by inserting a new sentence after the first sentence to read: The Building Valuation Data Table shown in the latest edition of the Building Safetv Journal published by the International Code Council shall be used to determine value. New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 13 of 19 R108.4 Related fees. Amend by inserting a new sentence after the first sentence to read: Any person who commences any work on a building before obtaining the necessary permits shall be subject to an additional fee, equal to the cost of the building permit. Section R112 Board of appeals. Delete the entire section. Refer to KMC Chapter 4.40. Section R -113.4 Violation penalties. Delete the entire section. Refer to KMC Chapter 4.40. R301.1.3 Engineered Design. Delete the entire section. R301.2.1.1 Design criteria. Delete the entire section. Table R301.2(1) Climatic and Geographic Design Criteria. Add the following information to the table: Ground snow load 70 PSF Wind Speed 110 mph Seismic Design Category D2 Subiect to damage from: Weathering Yes, severe Frost Line Depth 42" Termite No Decay No Winter Design Temperature -18 deg F Flood Hazards No Ice shield underlayment Yes required Air freezing index 3000 Mean annual temperature 35 degrees New Text Underlined; [DELETED TEXT BRACKETED] �,, Ordinance No. 2664 -2012 Page 14 of 19 R301.2.2.1.1 Alternate determination of seismic design category. Amend by deleting paragraphs R301.2.2.1.1, R301.2.2.1.2, R301.2.2.2, and Table R301.2.2.1.1 and replacing them with the following: The seismic design category for the City of Kenai shall be D2. R301.2.4 Flood Plain Construction Delete entire section. R302.1 Exterior Wall Location. Amend by deleting exceptions #3 and #4. R302.2 Exception. Amend by deleting the phrase "one hour fire resistance rated wall' and replacing it with "two hour fire resistance rated wall unless sprinklered per NFPA 13D." R302.2.4 Structural Independence. Delete Exception #5 and replace with: 5. Townhouses separated by a common 2 -hour fire resistance rated wall as provided in Section R302.2 or a 1 -hour wall as provided in Section R302.2 and sprinklered per NFPA 13D. R302.5.1 Opening Protection. Amend the second sentence by adding the words "self closing" before the words "solid wood doors." Table R302.6 Dwelling /Garage Separation. Amend by replacing all references to 1/2-inch material to 5/8 -inch material. R313 Automatic Fire Sprinkler Systems. Delete the entire section. R315.1. 315.2 and 315.3. Delete and replace as follows: New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 15 of 19 R315.1. At least one carbon monoxide detector or alarm shall be installed on each floor level. If a floor level contains bedrooms or sleeping rooms, at least one detector shall be located in the immediate vicinity of the sleeping area, outside of the bedrooms or sleeping rooms. Carbon monoxide detectors and alarms shall be installed in accordance with their listing. The alarm shall be clearly audible in all sleeping rooms, even if the intervening doors are closed. Exceptions: 1. Carbon monoxide detectors and alarms are not required in dwelling units that have all of the following: a. no combustion appliances b. no attached garage, c. no vehicle parking within 25 feet of any direct air intake opening. 315.2 Interconnection. In new construction, all carbon monoxide detectors and alarms located within a single dwelling unit shall be interconnected in such a manner that actuation of one alarm shall activate all of the alarms within the individual dwelling unit. 315.3 Power source. In new construction, carbon monoxide detectors and alarms shall receive their primary power from the building wiring if the wiring is served from a commercial source, and shall be equipped with a battery backup. Wiring shall be permanent and without a disconnecting switch other than what is required for overcurrent protection. In existing construction, carbon monoxide detectors and alarms may be powered by battery or a cord - and -plug with battery backup. R315.4 Alterations, Repairs, and Additions Add a new Section as follows: R315.4 Alterations, Repairs, and Additions: When interior alterations, repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be provided with the removal of the interior wall or ceiling finishes exposing the structure. R322 Flood Resistant Construction Delete entire section. R401.2 Requirements. New Text Underlined; [DELETED TEXT BRACKETED) Ordinance No. 2664 -2012 Page 16 of 19 Add the following exception: Wood foundations shall have a minimum 16 -inch x 10 -inch reinforced concrete footing. R402.1.3 Restraint for wood foundations. Add a new subsection, R402.1.3 Restraint for Wood Foundations, to read: Basement. A 4 -inch thick concrete slab poured against the studs. If a wooden screed is used, it shall be pressure treated Douglas fir or hem fir. Crawlspace. Option 1: A minimum 5 -inch wide by 4 -inch deep concrete curb poured against the inside face of the studs. The kicker shall be reinforced with a continuous horizontal No. 3 reinforcing bar. If the kicker is not poured with the continuous concrete footing, it may be poured later provided vertical #3 reinforcing bars x10 inches long shall be cast into the footing at 2 feet on center. They shall extend 2 inches above the top of the footing. The continuous #3 bar shall be secured to the vertical #3 bars. Option 2: Installation of preservative treated 4" x 4 "s with a minimum 1/2" x 12" galvanized anchor bolts at 24" O.C. installed in footing against the inside face of studs along the entire perimeter. Exception: The above need not apply if a suitable alternate design is prepared by an engineer registered in the State of Alaska and is approved by the Building Official. R402.1.4 Dampproofin¢ for wood foundation walls. Add a new subsection, R402.1.4 Dampproofmg for wood foundation walls, to read: Approved dampproofmg shall be applied over the below -grade portion of exterior basement and crawlspace walls prior to backfilling. A treated lumber or plywood strip shall be attached to the wall to cover the top edge of the approved dampproofmg The wood strip shall extend at least two (2) inches above and five (5) inches below finish grade level to protect the approved dampproofing from exposure to light and from mechanical damage at or near grade. The ioint between the strip and the wall shall be caulked full length prior to fastening the strip to the wall. Alternatively, brick, stucco, or other covering appropriate to the architectural treatment may be used in place of New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 17 of 19 the wood strip. The approved dampproofing shall extend down to the bottom of the concrete footing. R403.1.1 Minimum size. Amend the third sentence to read: All footings shall be at least 10 inches in thickness. R403.1.3 Seismic reinforcing. Delete the exception. R403.1.3.1 Foundations with stemwalls. Delete and replace with: Foundations with stemwalls shall be provided with a minimum of one No. 4 bar at the top of the wall for concrete masonry unit stemwalls, one No. 4 bar at the top of the wall for poured concrete stemwalls, and two No. 5 bars at the bottom of all footings. R403.1.3.2 Slabs -on- ground with turned -down footings. Amend the first sentence by changing the number "4" to "5." Amend the exception by deleting the phrase "one No. 5 bar" and replacing it with "two No. 5 bars." Further amend the exception by deleting the phrase or two No. 4 bars." R403.1.6 Foundation Anchorage. Amend by deleting the phrase "6 feet on center" and replacing it with "four feet on center." Further amend by deleting the measure of "1/2 inch" and replacing it with "S /8 inch." R702.3.5 Table Minimum Thickness and Application of Gypsum Board. Delete the column for nails as a fastener. R702.3.6 Fastening. Amend by adding the following sentence at the end of the paragraph: Gypsum board shall be attached with screws. Nails are not allowed. R806.1 Ventilation required. New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 18 of 19 Amend by adding the following sentence to the end of the paragraph: A non- ventilated roof system may be allowed as an alternate method when its design is droved by the Building Official. Chanters 11 -42. Amend by deleting Chapters 11 -42 in their entirety. Instead, refer to other applicable codes as adopted in KMC. 4.32.020 Building Official. The Building Official of this City shall have the powers, duties, and functions prescribed for the "Building Official" by the International Residential Code adopted by KMC 4.32.010, provided the powers, duties and functions may be performed by authorized representatives of the Building Official and under his or her supervision and control. 4.32.030 Fee schedule. Fees or charges under the International Residential Code as adopted by this Chapter shall be as set forth in the City's schedule of rates, charges and fees adopted by the City Council and the local amendments for section R108.2 in KMC 4.32.015. [SECTION R108.2 OF THE INTERNATIONAL RESIDENTIAL CODE ADOPTED BY THIS CHAPTER IS AMENDED TO READ: ADD THE FOLLOWING TO THE END OF THE PARAGRAPH: THE FEES FOR CONSTRUCTION OF GROUP R -3 AND GROUP U -1 OCCUPANCIES, OR PORTIONS THEREOF, AS SET FORTH IN THE CITY'S SCHEDULE OF FEES ADOPTED BY THE CITY COUNCIL. PLAN REVIEW FEES SHALL BE FIFTY PERCENT (50 %) OF THE BUILDING PERMIT FEE FOR GROUP R -3 AND GROUP U -1. PLAN REVIEW FEES SHALL BE PAID AT THE TIME APPLICATIONS FOR BUILDING PERMITS ARE SUBMITTED.] Section 3. Severability: If any part or provision of this ordinance or application thereof to any person or circumstances is adjudged invalid by any court of competent jurisdiction, such judgment shall be confined in its operation to the part, provision, or application directly involved in all controversy in which this judgment shall have been rendered, and shall not affect or impair the validity of the remainder of this title or application thereof to other persons or circumstances. The City Council hereby declares that it would have enacted the remainder of this ordinance even without such part, provision, or application. Section 4. Effective Date: Pursuant to KMC 1.15.070(fl, this ordinance shall take effect one month after adoption. New Text Underlined; [DELETED TEXT BRACKETED] Ordinance No. 2664 -2012 Page 19 of 19 ATTEST: S dr Mod h, C C Ci Cl rk .J PAT PORTER, MAYOR Introduced: December 19, 2012 Adopted: January 2, 2013 Effective: February 2, 2013 New Text Underlined; [DELETED TEXT BRACKETED] M Memorandum "Vllay with a Past, Giiy with a Future" To: City Council Through: Rick Koch, City Manager From: Larry Floyd, Building Official Date: December 11, 2012 210 Fidalgo Avenue, Kenai, Alaska 99611 -7794 � Telephone: 907- 283 -7535 / Fax: 907 - 283 -3014 www.d.kenai.ak.us 1I I I', 1992 Re: 2009 International Residential Code Adoption The City of Kenai has historically adopted the latest edition of the International Residential Code as the standard for the new home construction in the City. The City is adopting the other International Codes that work in conjunction with the Residential Code for consistency of enforcement. I therefore recommend the adoption of the 2009 International Residential Code as amended to consistently enforce the International Code standards for all construction in the City. i�