HomeMy WebLinkAboutOrdinance No. 2658-2012Suggested by: Administration
\ j CITY OF KENAI
KENAI AIASKA
ORDINANCE NO. 2658-2012
AN ORDINANCE OF THE COUNCIL OF THE CITY OF KENAI, ALASKA, AMENDING
CHAPTER 4.31, FUEL GAS CODE, BY ADOPTING THE 2009 EDITION OF THE
INTERNATIONAL FUEL GAS CODE AND MAKING LOCAL AMENDMENTS INCLUDING
ELIMINATING CHAPTERS 1 - 5 AND 8 AND THE APPENDICES OF THAT CODE SO
THAT ONLY CHAPTERS 6 AND 7 WILL APPLY IN THE CITY OF KENAI.
WHEREAS, the City previously adopted the International Fuel Gas Code, 2006
Edition, of the International Code Council, including appendices with certain local
amendments; and,
WHEREAS, the International Code Council updated the International Fuel Gas Code
in 2009; and,
WHEREAS, the City's Building Official recommends adoption of only Chapters 6 and 7
of the 2009 Edition of the International Fuel Gas Code in order to eliminate conflicts
between other uniform codes adopted by the City and to complement the City's
adoption of the Uniform Plumbing Code; and,
WHEREAS, it is in the best interest of the City to adopt only chapters 6 and 7 of the
2009 Edition of the International Fuel Gas Code in order to protect the health, safety,
and welfare of its citizens.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF KENAI,
ALASKA, as follows:
Section 1. Form: This is a Code ordinance.
Section 2. Amendment of Chapter 4.31 of the Kenai Municipal Code: The Kenai
Municipal Code, Chapter 4.3 1, Fuel Gas Code, is hereby amended as follows:
Chapter 4.31
FUEL GAS CODE
4.31.010 Adoption.
4.31.015 Local Amendments to the 2009 International Fuel Gas Code.
4.31.020 Building Official.
4.31.030 Fee schedule.
4.31.010 Adoption.
There is hereby adopted for the purpose of establishing rules and regulations
for the approval, design, installation, construction, maintenance, alteration, and repair
of specific fuel gas appliances, gaseous hydrogen systems, JINSTALLATION AND
Ordinance No. 2658-2012
Page 2 of 5
MAINTENANCE OF FUEL GAS PIPING SYSTEMS, FUEL GAS UTILIZATION,] and
related accessories [AS DEFINED UNDER SCOPE IN] that certain code known as the
"International Fuel Gas Code," 200[6]9 Edition, of the International Code Council [,
INCLUDING THE APPENDICES,] except for such portions as are hereafter deleted,
modified, or amended; and the same is hereby adopted and incorporated as fully as if
set out verbatim herein.
4.31.015 Local Amendments to the International Fuel Gas Code.
[SECTION 103 DEPARTMENT OF INSPECTION.
111101:8 1 zl �1 <• <I Y1 7 �.`1X�C�J�
SECTION 109 MEANS OF APPEAL.
DELETE ENTIRE SECTION. REFER TO "CHAPTER 4.40 OF KMC.
201.3 TERMS DEFINED IN OTHER CODES.
DELETE REFERENCE TO INTERNATIONAL ELECTRICAL CODE AND INSERT
REFERENCE "ELECTRICAL CODE AS ADOPTED BY KMC." DELETE REFERENCE TO
INTERNATIONAL PLUMBING CODE AS ADOPTED BY KMC."
fc 1MI lQl III 11 VAR I DIJ
DELETE THE WORDS "IN ACCORDANCE WITH THE INTERNATIONAL
ENERGY CONSERVATION CODE."
301.6 PLUMBING CONNECTIONS.
DELETE REFERENCE TO INTERNATIONAL PLUMBING CODE AND INSERT
REFERENCE "PLUMBING CODE AS ADOPTED BY KMC."
304.6 OUTDOOR COMBUSTION AIR.
ADD THE FOLLOWING TO THE END OF THE PARAGRAPH: "COMBUSTION
AIR SHALL NOT BE OBTAINED FROM THE ATTIC, UNLESS PRIOR APPROVAL IS
OBTAINED FROM THE ADMINISTRATION AUTHORITY."
304.11 COMBUSTION AIR DUCTS.
DELETE THE EXCEPTION TO ITEM 1.
306.3.1 ELECTRICAL REQUIREMENTS.
New Text Underlined; [DELETED TEXT BRACKETED]
Ordinance No. 2658-2012
Page 3 of 5
DELETE REFERENCE TO INTERNATIONAL ELECTRICAL CODE AND INSERT
REFERENCE "ELECTRICAL CODE AND INSERT REFERENCE "ELECTRICAL CODE AS
ADOPTED BY KMC."
306.4.1 ELECTRICAL REQUIREMENTS.
DELETE REFERENCE TO INTERNATIONAL ELECTRICAL CODE AND INSERT
REFERENCE "ELECTRICAL CODE AND INSERT REFERENCE "ELECTRICAL CODE AS
ADOPTED BY KMC."
306.5.2 ELECTRICAL REQUIREMENTS.
DELETE REFERENCE TO INTERNATIONAL ELECTRICAL CODE AND INSERT
REFERENCE "ELECTRICAL CODE AND INSERT REFERENCE "ELECTRICAL CODE AS
ADOPTED BY KMC."
kiII9pysllW `0xwI[17►`0
DELETE REFERENCE TO INTERNATIONAL ELECTRICAL CODE AND INSERT
REFERENCE "ELECTRICAL CODE AND INSERT REFERENCE "ELECTRICAL CODE AS
ADOPTED BY KMC."
404.9 MINIMUM BURIAL DEPTH.
II��y11T.Y11T.� Ilii►�N�N/:r�[e7�fiiE►4tiIC�3iiB�ti
404.17 UNDERGROUND PIPING SYSTEM INSTALLATION.
ADD A NEW SUBSECTION 404.17:
AT ALL POINTS WHERE FUEL GAS PIPING ENTERS OR LEAVES THE
GROUND, THERE SHALL BE INSTALLED, ABOVE GROUND, A CONNECTION
CAPABLE OF ABSORBING RELATIVE MOTION DUE TO FROST HEAVE ACTION.
SUCH CONNECTORS SHALL BE OF A TYPE APPROVED BY THE BUILDING
OFFICIAL AND INSTALLED IN SUCH A MANNER TO ABSORB A 6 -INCH (152 MM)
DISPLACEMENT IN ANY DIRECTION. A WIRE BRAIDED KINK -PROOF FLEXIBLE
CONNECTION WITH WOVEN JACKET AND OIL PROOF SYNTHETIC TUBE AND
COVER AND NEOPRENE LINER MAY BE USED. SUPPORTING WIRE SHALL RUN THE
FULL LENGTH OF HOSE. HOSE -TO -PIPE CONNECTORS ARE TO BE OF THE
REMOVABLE METAL COMPRESSION TYPE. TEMPERATURE RANGE SHALL BE —40
DEGREES F TO +250 DEGREES F.
404.18 PIPING SYSTEM INSTALLATION; FLEX CONNECTORS.
ADD A NEW SUBSECTION AS FOLLOWS:
New Tent Underlined; [DELETED TEXT BRACKETED]
Ordinance No. 2658-2012
Page 4 of 5
404.18 FLEX CONNECTORS. FLEX CONNECTORS LISTED FOR OUTDOOR USE
MAY BE USED BETWEEN METER AND HOUSE MAIN. NO FLEX CONNECTOR MAY
PASS THROUGH ANY WALL, PARTITION, PANEL, OR OTHER BARRIER. SOLID
FITTINGS SHALL BE USED ON EACH END.
406.4.1 TEST PRESSURE.
REPLACE THE MINIMUM TEST PRESSURE OF 3 PSIG WITH 10 PSIG AND ADD
THE FOLLOWING SENTENCE AT THE END OF THE PARAGRAPH.
REQUIRED PRESSURE TESTS OF 10 PSIG SHALL BE PERFORMED WITH
GAUGES OF 1/10 -POUND INCREMENTATION OR LESS.
409.5 EQUIPMENT SHUTOFF VALVE.
DELETE THE EXCEPTION.
502.8 VENTS; VENT INSULATION.
ADD A NEW SUBSECTION AS FOLLOWS:
502.8 VENT INSULATION. UNLESS A VENT LISTED FOR EXTERIOR USE IN
COLD WEATHER CLIMATES IS INSTALLED, A VENTING SYSTEM INSTALLED
EXTERIOR TO THE BUILDING, OUTSIDE THE THERMAL ENVELOPE, SHALL BE
INSTALLED IN AN INSULATED (R-19 MINIMUM) SHAFT. THE PORTION OF THE
VENT SYSTEM THAT IS ABOVE THE LAST ROOF AND ITS PROJECTED PLANE NEED
NOT BE ENCLOSED. THE PORTION OF THE VENTING SYSTEM PASSING THROUGH
AN ATTIC SPACE NEED NOT BE INSULATED OR ENCLOSED.
502.9 VENTS; ICE DAMAGE.
ADD A NEW SUBSECTION AS FOLLOWS:
502.9 ICE DAMAGE. VENT TERMINATIONS THAT PENETRATE A METAL
ROOF WITH A PITCH SHALL BE PROTECTED BY AN ICE DAM OR DEFLECTOR OF
AN APPROVED TYPE ACCEPTABLE TO THE ADMINISTRATIVE AUTHORITY.]
Amend by deleting Chapters 1-5, Chapter 8, and Appendices A — D.
4.31.020 Building Official.
The Building Official of this City shall have the powers, duties, and functions
prescribed for the "Code Official" by the International Fuel Gas Code adopted by KMC
4.31.010, provided the powers, duties and functions may be performed by authorized
representatives of the Building Official and under his or her supervision and control.
New Text Underlined; [DELETED TEXT BRACKETED]
Ordinance No. 2658-2012
Page 5 of 5
4.31.030 Fee schedule.
tSECTION 106.5 OF THE INTERNATIONAL FUEL GAS CODE ADOPTED BY
THIS CHAPTER IS AMENDED TO READ:
IF A BUILDING PERMIT IS ISSUED, THESE FEES SHALL BE CONSIDERED AS
PAID AS A PART OF SUCH PERMIT FEE. IF NO SUCH BUILDING PERMIT IS ISSUED,
THE FEE SHALL BE COMPUTED ACCORDING TO TABLE 1-A AT KMC 4.05.030(B).]
Fees or charges under the International Fuel Gas Code as adopted by this
Chapter shall be as set forth in the City's schedule of rates, charges and fees adopted
by the City Council.
Section 3. Severability: If any part or provision of this ordinance or application
thereof to any person or circumstances is adjudged invalid by any court of competent
jurisdiction, such judgment shall be confined in its operation to the part, provision, or
application directly involved in all controversy in which this judgment shall have been
rendered, and shall not affect or impair the validity of the remainder of this title or
application thereof to other persons or circumstances. The City Council hereby
declares that it would have enacted the remainder of this ordinance even without such
part, provision, or application.
Section 4. Effective Date: Pursuant to KMC 1.15.070(f), this ordinance shall take
effect one month after adoption.
PASSED BY THE COUNCIL OF THE CITY OF KENAI, ALASKA, this 2nd day of
January, 2013.
CCS 422te�ZZAJ
PAT PORTER, MAYOR
ATTEST:
S dr Modigh, CMC
CiqKCArk
�J
Introduced: December 19, 2012
Adopted: January 2, 2013
Effective: February 2, 2013
New Text Underlined; [DELETED TEXT BRACKETED]
M
Memorandum
""Villaye with a Past, C# with a Future
210 Fidalgo Avenue, Kenai, Alaska 99611-7794
Telephone: 907-283-7535 / Fax: 907-283-3014
w .ci.kenai.ak.us 1IIII.'
1992
To: City Council
nThrough: Rick Koch, City Manager
From: Larry Floyd, Building Official q
Date: December 11, 2012
Re: 2009 International Fuel Gas Code Adoption
The City has a deferral agreement with the State of Alaska which requires the City of
Kenai to adopt and enforce code standards no less stringent than those enforced by the
State. The State of Alaska adopted standards of the 2009 International Fuel Gas Code in
November of this year.
I therefore recommend the adoption of the 2009 International Fuel Gas Code as amended
by the State of Alaska in order to comply with our deferral agreement and to consistently
enforce the code standards in effect throughout the State.